Products catalog

Switched-mode power supply 24V 1.5A enclosed MEAN WELL

  • Switched-mode power supply 24V 1.5A enclosed MEAN WELL

    Manufacturer
    Mean Well
    • General
    • ModelLRS-35-24
    • Output Voltage24V DC
    • Rated Current1.5A
    • Current Range0 – 1.5A
    • Rated Power36W
    • Ripple & Noise (max.)150 mVp-p
    • Voltage Adjustment Range21.6 – 28.8V
    • Voltage Tolerance±1.0%
    • Line Regulation±0.5%
    • Load Regulation±0.5%
    • Setup, Rise Time2000 ms, 30 ms @ 115 VAC; 1000 ms, 30 ms @ 230 VAC (full load)
    • Hold-up Time30 ms @ 230 VAC; 12 ms @ 115 VAC (full load)
    • Input Voltage Range85 – 264 VAC / 120 – 373 VDC
    • Input Frequency47 – 63 Hz
    • Efficiency (Typ.)88%
    • AC Current0.7A @ 115 VAC / 0.42A @ 230 VAC
    • Inrush Current (Typ.)Cold start 45A @ 230 VAC
    • Leakage Current<0.75 mA @ 240 VAC
    • Overload Protection110 – 150% rated power (hiccup mode, auto recovery)
    • Overvoltage Protection28.8 – 33.6V (shut down, re-power to recover)
    • Working Temperature–30°C to +70°C (derating above 50°C)
    • Working Humidity20 – 90% RH non-condensing
    • Storage Temperature / Humidity–40°C to +85°C / 10 – 95% RH
    • Temperature Coefficient±0.03% / °C (0 – 50°C)
    • Vibration Resistance10 – 500Hz, 5G, 10 min/cycle, 60 min per X, Y, Z axes
    • Isolation VoltageI/P–O/P: 4kVAC; I/P–FG: 2kVAC; O/P–FG: 1.25kVAC
    • Insulation Resistance100 MΩ @ 500VDC / 25°C / 70% RH
    • EMC EmissionEN55032 Class B, EN61000-3-2, EN61000-3-3, EN55014, GB17625.1, KN32, KN35
    • EMC ImmunityEN61000-4-2 to -6, -8, -11, EN61000-6-2, EN55035 (heavy industry level)
    • Safety StandardsUL62368-1, TUV EN62368-1, EN60335-1, EN61558-1/-2-16, GB 4943.1, BIS IS13252(Part1), EAC, KC (for LRS-35-12/24 only)
    • Case DesignMetal mesh, 1U low profile (30 mm)
    • CoolingMethod Free air convection (fanless)
    • Dimensions99 × 82 × 30 mm (L × W × H)
    • Weight0.23 kg; Packing: 60 pcs / 14.8 kg / 0.88 CUFT
    • FeaturesHigh efficiency (88%), LED indicator, <0.2W no-load power, 300VAC surge input for 5 sec, overvoltage category III, 5G vibration proof, 100% full load burn-in test
    • Operating AltitudeUp to 5000 meters
    • ApplicationsIndustrial automation, control systems, household appliances, instrumentation
    • Warranty3 years