Products catalog

  • Security system kit SECOLINK GSV4B+KM20B+CAS6

    Manufacturer
    Secolink
  • Control panel
    In-built wired zones on board5
    Maximum wired zones7
    PGM on board1
    Maximum PGM3
    User codes5
    Defaulting user codeYes
    Key switch zoneYes
    Partitions1
    System timers16
    Event log size256 (with keypad 512)
    Data bus protocolKRBUS
    Reporting to CMS formatCID via GPRS
    Total number of protocols, used for CMS reportingE2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA
    Compatible with SG-SYSTEM II, III IP cardYes
    Alarm message for end userGSM calls, SMS
    Alarm message for end user by voice clipYes
    Voice guideNo
    Recordable audio alarm messagesYes
    Available language for SMSEnglish, National
    Remote system control by Android or IPhone applicationYes
    Zone speed (sensitivity)0.1 - 2.5 sec.
    Zone loop (detector) typeNC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL
    Arming modeAway, Max Away, Night, Stay.
    Zone definitionEntry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature.
    Zone attributesEnable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night.
    PGM definitionFire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, wxit arm status, full arm status, arm/disarm acknowledge, power supply, resettable power supply, fire power supply, timer, mono/bi switch.
    PGM attributesInversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, arm notification, disarm notification, clear alarm notification.
    Rated voltage of power supply (AC)~20 V
    Minimum AC voltage~16 V
    Maximum AC voltage
    (Note: higher than ~22 V voltage can damage GSV4)
    ~22 V
    Maximum long term output current of GSV4
    (I+AUX + I+BELL + battery charge)
    0.7 A
    Maximum current of slow blowing fuse used in primary AC250 mA
    Maximum AC power consumption<30 mA
    Minimum voltage on +AUX, +BELL, outputs12 V
    Maximum voltage on +AUX, +BELL, outputs13.9 V
    Maximum current out of +AUX0.25 A
    Maximum current out of +BELL (without battery)0.2 A
    Maximum current out of +BELL (with battery)2:00 AM
    Short circuit, overload protection of +BELL, +AUXelectronic
    Battery charge +BELL, +AUX current measurementYes
    Failed (waste) backup battery disconnectionYes
    Maximum battery charging current0.25 A
    Maximum current of fast blowing fuse used in battery3.15 A
    GSV4 disconnects battery when it’s voltage less than9.5 V
    Recommended backup power supply12 V, 7 Ah / 20 Hr
    Operational complianceEN50131, Grade2
    Overall dimensions W x H in mm120 x 64
    Environmental complianceROHS
    Operating temperatureFrom -10oC to +50oC
    Interface for control panel settings programmingUSB
    Interface for control panel firmware updateUSB
    Remote control panel settings programmingYes, via www.alarmserver.net
    Keypad
    On-Board zones2
    On-Board PGM-
    Ambient temperature measurement-
    LCD type2 rows 16 symbols each
    Keys in keypad20
    Programmable fast keys (F-Keys)32
    Data bus protocolKRBUS
    Zone loop (detector) typeNC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL
    Maximum wiring distance to CP300 m
    Power supply9 - 14 V
    Voltage measurement on keypadYes
    Current consumptionBacklight on 100 mA, Baclight off < 50 mA.
    On-Board sounderBuzzer
    Backlight color Display = blue, keypad = yellow
    Character setLatin, Russian, Greek, East European, West European, Azeri, Turkish, Scandinavian.
    User interface typeAdvanced, Simple, Baltic, Asian.
    Overall dimensions W x H in mm115 x 95
    Environmental complianceROHS
    Operating temperature0oC up to +50oC
    Interface for keypad settings programmingUSB
    Interface for keypad firmware updatingUSB