Products catalog

  • Control panel SECOLINK S32eT

    Manufacturer
    Secolink
    • General
    • Security system conceptHibridinė modulinė
    • Number of wired zones on the board5/10 (dvigubinant)
    • Fire zone for connecting two-wire smoke detectors1
    • Number of built-in wireless zones32
    • Maximum number of zones in the system32
    • Number of PGM outputs on the board3
    • Maximum number of PGM outputs in the system16
    • Number of users + installer codes31+1
    • Attack codeYra
    • Recovery of user and installer codesYra
    • Key-switch area (key-switch)Yra
    • Areas4
    • Common corridor areaYra
    • Number of timers in the system16
    • Maximum number of control panels/modules in the system5
    • Compatibility with control panelsVisi SECOLINK valdymo pultai
    • Event log volumeCentralėje - 256, komplekte su vald. pultu - 512
    • Interface with transmitters and communicators of other manufacturersNėra
    • Data bus protocolKRBUS
    • The area of ​​the sensor (roller) that detects the lifting of blindsYra
    • Vibration detection sensor areaYra
    • Sensitivity (speed) of the vibration detection zone0,01 - 0,25 sek.
    • Sensor area sensitivity (speed)0,1 - 2,5 sekundės
    • Sensor connection loop typesNC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Roller, Vibracija, Wireless
    • Protection modesIšvykę, ilgam išvykę, naktis, namuose.
    • Modem versionsModemas skirtas 2G tinklui ir LTE tinklo Cat-M1 potinkliui.
    • Has an integrated SIM card (hereafter eSIM)Taip
    • Has a slot to insert a separate user SIM cardTaip (dydis: micro SIM)
    • Nominal power supply voltage (AC) of the control unit~20 V
    • Minimum panel supply voltage (AC) (note: at ~16 V, the maximum direct current generated by the panel power supply is 0.5 A)~16 V
    • Maximum power supply voltage (AC) of the control unit (note: a voltage higher than ~22 V can damage the control unit)~22
    • Requirements for a power transformer≥30 VA Dėmesio: S32 serijos centralės skirtos montuoti į CAS6 plastikinę dėžę. Šių centralių negalima montuoti į CAS4 plastikinę dėžę dėl joje naudojamo mažos galios transformatoriaus.
    • Maximum long-term control unit output current (I+AUX + I+BELL + IBATTERY CHARGE)≤1 A
    • Maximum AC primary slow-blow fuse current250 mA
    • Maximum current consumed from the AC mains150 mA
    • Minimum voltage of +AUX, +BELL outputs12 V
    • Maximum voltage of +AUX, +BELL outputs13,9 V
    • Maximum outgoing +AUX current+0,8 A
    • Maximum short-term output +BELL current (with battery)+2 A
    • Maximum inrush current of -PGM1-0,15 A
    • Maximum inrush current of -PGM2-0,15 A
    • +BELL, +AUX short circuit, overload protectionElektroninė
    • Battery charging, +BELL, +AUX current measurementYra
    • Disconnecting a faulty batteryYra
    • Maximum battery charging current+0,2 A
    • Maximum current of the battery circuit fast-blow fuse3,15 A
    • The control unit disconnects the battery when the battery voltage is below9,5 V
    • Product compliance with standardsEN50131, Grade2
    • A backup power supply is recommended12 V, 2,2 - 7Ah
    • Overall dimensions W x H mm145 x 77
    • Compliance of the product with environmental protection standardsROHS
    • Operating temperatureNuo -10oC iki +50oC
    • Remote programming of control panel settingsYra
    • Product statusGaminamas
    • Interface with a computer (programming, firmware update)USB micro-B